|
|
THE INVOLVED TRUCKS WERE MANUFACTURED WITH A CERTAIN PORTION OF SPECIFIED FLOOR PAN INSULATION MATERIAL (BENEATH THE RIGHT FRONT PASSENGER SEAT) OMITTED. BECAUSE OF THIS OMISSION, A SECTION OF THE SHEET METAL FLOOR PAN WAS LEFT EXPOSED OVER THE EXHAUST SYSTEM IN AN AREA OF POSSIBLE PASSENGER CONTACT. ...more details
| Recall Reason |
STRUCTURE |
| Recall Date |
MAY 21, 1981 |
| Model Affected |
F100 |
| Potential Units Affected |
130 |
|
Recall Summary
THE INVOLVED TRUCKS WERE MANUFACTURED WITH A CERTAIN PORTION OF SPECIFIED FLOOR PAN INSULATION MATERIAL (BENEATH THE RIGHT FRONT PASSENGER SEAT) OMITTED. BECAUSE OF THIS OMISSION, A SECTION OF THE SHEET METAL FLOOR PAN WAS LEFT EXPOSED OVER THE EXHAUST SYSTEM IN AN AREA OF POSSIBLE PASSENGER CONTACT.
|
|
Consequence
|
|
Remedy
THE DEALER WILL INSTALL A REVISED DESIGN FLOORPAN INSULATOR PAD AT NO CHARGE TO OWNER.
|
|
Notes
FORD MOTOR COMPANY
|
THE REINFORCEMENT FOR THE IN-BOX SPARE TIRE CARRIER MAY HAVE BEEN ATTACHED USING INCORRECT HEX HEAD BOLTS. IF THE CARRIER AND REINFORCEMENT ATTACHING BOLTS ARE INCORRECT, THE POTENTIAL EXISTS FOR THE TIRE SIDEWALL TO BE DAMAGED OR WEAKENED BY EXTENDED CONTACT WITH THE SHARP EDGES OF THE BOLT HEADS. ...more details
| Recall Reason |
EQUIPMENT:MECHANICAL:CARRIER/RACK |
| Recall Date |
MAR 15, 1982 |
| Model Affected |
F100 |
| Potential Units Affected |
12500 |
|
Recall Summary
THE REINFORCEMENT FOR THE IN-BOX SPARE TIRE CARRIER MAY HAVE BEEN ATTACHED USING INCORRECT HEX HEAD BOLTS. IF THE CARRIER AND REINFORCEMENT ATTACHING BOLTS ARE INCORRECT, THE POTENTIAL EXISTS FOR THE TIRE SIDEWALL TO BE DAMAGED OR WEAKENED BY EXTENDED CONTACT WITH THE SHARP EDGES OF THE BOLT HEADS.
|
|
Consequence
|
|
Remedy
DEALER WILL REPLACE BOLTS AND ANY DAMAGED SPARE TIRES AT NO COST TO OWNER.
|
|
Notes
FORD MOTOR COMPANY
|
DURING A CHANGE IN ASSEMBLY PROCEDURES, CERTAIN OF THE MID-SHIP FUEL TANK STRAPS MAY HAVE BEEN IMPROPERLY INSTALLED OR MISLOCATED. AS A RESULT, THEY FAIL TO CONFORM TO FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". IN THE EVENT OF A COLLISION, EXCESSIVE FUEL SPILLAGE MAY OCCUR. ...more details
| Recall Reason |
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:MOUNTING |
| Recall Date |
NOV 10, 1980 |
| Model Affected |
F100 |
| Potential Units Affected |
6260 |
|
Recall Summary
DURING A CHANGE IN ASSEMBLY PROCEDURES, CERTAIN OF THE MID-SHIP FUEL TANK STRAPS MAY HAVE BEEN IMPROPERLY INSTALLED OR MISLOCATED. AS A RESULT, THEY FAIL TO CONFORM TO FEDERAL MOTOR VEHICLE SAFETY STANDARD NO. 301, "FUEL SYSTEM INTEGRITY". IN THE EVENT OF A COLLISION, EXCESSIVE FUEL SPILLAGE MAY OCCUR.
|
|
Consequence
|
|
Remedy
DEALER WILL INSPECT AND, IF NECESSARY, RELOCATE FUEL TANK STRAPS WITHOUT CHARGE TO OWNER.
|
|
Notes
FORD MOTOR COMPANY
|
|